Questions? Feedback? powered by Olark live chat software

Preventative Maintenance Kit for Z Wave Q

(No reviews yet) Write a Review
$995.00
$1,164.00
Brand:
Condition:
New

Preventative Maintenance Kit for Z WaveQ

This Preventative Maintenance Kit for the Zimmer MedizinSystems Z Wave Q is designed to help keep your unit running optimally and to protect the investment you made in your Zimmer MedizinSystems Z Wave Q device.

Each of the items included in the set may be purchased separately, but are offered at a significant savings when bundled in this kit.

Save $169 by purchasing the Z Wave Q maintenance items as a bundled kit. Retail price of maintenance kit items when purchased individually is $1,164. When purchased together in this kit at the price of $995, you save $169.

 

Complete Set Consists of:

•  1 bottle of Zimmer MedizinSystems lotion (oil)

•  Set of 25 grey silicone caps for 39mm applicator head

•  3 x 39mm applicator heads for Z Wave Q hand piece

•  Wave Maintenance Guidelines trifold brochure

 

Zimmer MedizinSystems Z Wave Q Maintenance Kit Items: For long life of your Z Wave device

Zimmer MedizinSystems Lotion

Zimmer MedizinSystems Lotion comes in a white Zimmer MedizinSystems bottle, labeled “Lotion”. The bottle is conveniently sized to be held in the Z Wave SysCart Q and SysCart Q accessory holders behind the monitor. Zimmer MedizinSystems Lotion is a lubricant designed to allow a hand piece to comfortably and safely move across the skin. It is not a conductor of energy, but avoids uncomfortable dragging across the skin and prevents any possible abrasion. It should be used sparingly, only using enough so that the operator feels the hand piece glide without dragging. It typically requires only 3-5 drops, depending on the size of the treatment area and the dryness of the skin. If the operator senses drag during treatment, simply add a few more drops. Excessive amounts of oil are unnecessary. Excessive oil use can make for splatter to the surrounding area and can make it more likely for oil to migrate inside the hand piece. To apply the oil, place the 3-5 drops on the area to be treated. Hold the hand piece in the other hand. Use the hand piece to spread the oil. Operator's foot should be off the pedal, but ready to depress it. Once the oil is evenly spread, keep moving the hand piece as you step on the pedal to begin treatment.

 

Set of 25 Grey Silicone Caps for 39mm Applicator Head

The Z Wave Q silicone cap for the hand piece is specifically designed to be applied over the 39mm applicator head of the Z Wave Q hand piece. It is required if the treatment is applied using Zimmer MedizinSystems Lotion or other lubricants. The silicone caps allow for an optimal energy transfer to the patient and they protect the applicator head. 

 

3 x 39 mm Applicator Heads

The applicator heads are specifically designed for use with the Zimmer MedizinSystems Wave Q hand piece. It is essential that the applicator head is screwed tightly into the hand piece. If lotion or other lubricants are being used for patient treatments, the grey silicone cap is to be applied over the 39mm applicator head. This will allow for an optimal energy transfer to the patient and to protect the applicator head. Each Z Wave Q maintenance kit comes with 3 applicator heads, all 39mm. 

The applicator head must be replaced after a certain period of use. Minor or slight deformation or shortening of the rear impact dome does not affect functionality, but as deformation or shortening of the rear impact dome becomes greater, the applicator head needs to be replaced.

The Z Wave hand piece is an ergonomically designed patient energy transfer system and is used in conjunction with the 39mm applicator head and the silicone cap. The Z Wave’s electromagnetic generator is primarily designed to temporarily reduce the appearance of cellulite and to enhance body shaping results. To treat cellulite, the Zimmer MedizinSystems Z Wave Q unit transmits powerful sound waves into the tissue. The Radial Pulse energy is delivered via the electromagnetic applicator. The energy then spreads out radially to enhance the treatment effect.

 

Z Wave Maintenance Guidelines Trifold Brochure

Instructions and practical tips with illustrations for best practices to help extend the life of your Z Wave Q unit and to protect your investment. This informational brochure may also be obtained separately by contacting us. You can always reach us quickly by phone or email with inquiries.

 

Items Included In This Kit Work With:

Zimmer MedizinSystems Z Wave Q Radial Pulse Therapy Device. (Sold separately.)  The items in the Zimmer MedizinSystems Z Wave Q Maintenance Kit are intended for use only with the Zimmer MedizinSystems Z Wave Q system. Only Zimmer MedizinSystems Z Wave Q models should be equipped with these items. Other Zimmer MedizinSystems Z Wave models should be fitted with their corresponding Z Wave Maintenance Kit items.

 

For more information on the Zimmer MedizinSystems Z WaveQ device, please visit our website at www.zimmerusa.com, contact us at info@zimmerusa.com, or call us toll free at 800-327-3576.

For complete warranty details please see "Terms and Conditions of Sale" in the "Contact Us" section of this website. All sales on parts are final. Call # 800-327-3576 or email info@zimmerusa.com with any questions. Please visit www.zimmerusa.com to learn more about the ZWave units.